Make your HMI/SCADA/MES or Other Software Appear to be a Modbus Device
This driver is only available as part of the following TOP Server driver suites:
100 channels, 247 devices each
All Modbus types supported
CSV import, auto tags
Stable across all networks
The Modbus RTU Server Serial driver works in conjunction with TOP Server to provide data exchange between OPC UA, OPC DA, SuiteLink and DDE clients and Modbus RTU Client devices using the Modbus RTU Serial protocol over direct COM: port RS-232/422/485 connections or via Ethernet/Serial Converters, Ethernet Device Servers, or Ethernet/Serial Terminal Servers.
This driver allows client software connected to the TOP Server to appear as Modbus RTU devices on the Modbus RTU network. This unsolicited mode allows the TOP server to receive data by exception from Modbus RTU Clients, whether they are actual PLCs or devices acting as Modbus RTU Clients or other software applications capable of sending Modbus RTU Client requests. Data integrity is ensured using extensive error handling.
If you need TOP Server to initiate data exchange with Modbus RTU Devices then you would use the Modbus RTU Client Driver, also part of the TOP Server Modbus Suite, so there's no added cost to do either option or both.
Proven benefits that help you deploy faster and operate more reliably
Supports Modbus function codes in decimal, 01, 02, 03, 04, 05, 06, 08, 15, 16, and hexadecimal, 01, 02, 03, 04, 05, 06, 08, 0F, 10.
Full address range support including 0xxxx output coils, 1xxxx input coils, 3xxxx internal registers, and 4xxxx holding registers.
Supports both decimal and hexadecimal addressing formats.
Supports all memory types and data types including float, long word, and BCD.
Base Modbus device model supports 32-bit data types using two registers.
Supports string data types for internal registers.
Automatic tag database generation using CSV import.
Supports dynamic tag configuration directly from client applications.
"Exceptionally helpful, best international support I've ever received and prompt."
Jordan H
CS Solutions
Everything you need for reliable Modbus TCP Ethernet connectivity
Supports up to 100 channels and 247 devices per channel, with limits based on available system resources.
COM port range from 1 to 999 with station numbers supported from 1 to 247.
Supports Modbus RTU multi drop and Ethernet encapsulation via converters, device servers, or terminal servers.
Includes word order swapping for floating point and long data types, with support for multiple Modbus slave devices.
Protocols
Supports Modbus RTU and JBUS RTU serial protocols.
RS 232
Serial communication over RS 232.
RS 422
Serial communication over RS 422.
RS 485
Serial communication over RS 485.
Ethernet Encapsulation
Supports Ethernet encapsulated serial using converters, device servers, or terminal servers.
Note: Supports any Modbus TCP/IP Ethernet-capable device. Includes specialized support for Applicom models, flow measurement devices, and gateway/bridging configurations.
Everything you need to get started, configure, and troubleshoot your driver
Watch step-by-step video tutorials covering installation and configuration
View →Get started quickly with TOP Server
View →Troubleshooting tips and solutions for TOP Server
View →Complete driver documentation with setup instructions and configuration examples
Download →View the complete TOP Server release history and version information
View →