Dream Report integrates a robust communication kernel to collect data and alarms from multiple real time and historian sources. It uses OPC, OLE and ODBC standards to connect and collect data from different suppliers.
Dream Report’s OPC client driver supports the most popular OPC specifications including OPC DA, AE and HDA (data access, alarm & event, history data access). Moreover, custom drivers are available to leverage native history from SCADA systems, DCS, RTU and more.
Vendor |
Data Source Name |
Driver Type |
Comments |
Afcon |
PCIM SCADA/PULSE |
Real-Time values |
Native, proprietary (OEM only) |
Afcon |
PCIM SCADA/PULSE |
Real-Time alarms |
Native, proprietary (OEM only) |
Afcon |
PCIM SCADA/PULSE |
Historical values |
Native, proprietary (OEM only) |
Afcon |
PCIM SCADA/PULSE |
Historical alarms |
Native, proprietary (OEM only) |
ARC Informatique |
PcVue OPC |
Real-Time values |
Custom, OPC based |
ARC Informatique |
PcVue HDS server |
Historical values |
Direct |
ARC Informatique |
PcVue HDS server |
Historical alarms |
Direct |
ARC Informatique |
PcVue SCADA |
Real-Time values |
Native, web services |
ARC Informatique |
PcVue SCADA |
Real-Time alarms |
Native, web services |
ARC Informatique |
PcVue SCADA |
Historical values |
Native, web services |
AspenTech |
Aspen.IP21 |
Historical values |
Direct, ODBC based |
AVEVA |
Application Server |
Real-Time values |
Native, MX (with Galaxy) |
AVEVA |
Alarm DB Logger |
Historical alarms |
A2ALMDB, Direct |
AVEVA EDGE (InduSoft HMI) |
AVEVA EDGE (InduSoft HMI) |
Historical values |
Direct |
AVEVA EDGE (InduSoft HMI) |
AVEVA EDGE (InduSoft HMI) |
Historical alarms |
Direct |
AVEVA EDGE (InduSoft HMI) |
AVEVA EDGE (InduSoft HMI) |
Real-Time values |
Native, proprietary |
AVEVA |
InTouch |
Real-Time values |
Native, SuitLink |
AVEVA |
InTouch |
Historical alarms |
WWALMDB, Direct |
AVEVA |
InTouch Machine Edition |
Historical values |
Direct |
AVEVA |
InTouch Machine Edition |
Historical alarms |
Direct |
AVEVA |
InTouch Machine Edition |
Real-Time values |
Native, proprietary |
AVEVA |
Mobile Operator |
Historical values |
Direct |
AVEVA |
InSight (Historian Online) |
Historical values |
OData |
AVEVA |
InSight (Historian Online) |
Historical alarms |
OData |
AVEVA |
Historian |
Historical alarms |
ODBC based |
AVEVA |
Historian |
Historical alarms |
Native SDK, OData |
AVEVA |
Historian |
Historical values |
Direct |
AVEVA |
PI WEB API |
Historical values |
Web services |
AVEVA |
PI |
Historical values |
Direct, ODBC based |
AVEVA |
PI Asset Framework |
Real-Time values |
Native, proprietary |
AVEVA |
PI Asset Framework |
Historical values |
Native, proprietary |
AVEVA |
PI Asset Framework |
Event frames |
Native, proprietary |
AVEVA |
PI Asset Framework |
Historical alarms |
Native, proprietary |
AVEVA |
PI Asset Framework |
Historical values |
Native, proprietary (SDK 2018) |
AVEVA |
PI Asset Framework |
Real-Time values |
Native, proprietary (SDK 2018) |
AVEVA |
Plant SCADA |
Historical values |
Direct, ODBC based |
AVEVA |
Plant SCADA |
Historical alarms |
Direct, ODBC based |
AVEVA |
Plant SCADA |
Historical values |
Legacy historical values |
AVEVA |
Plant SCADA |
Real-Time values |
Native, proprietary |
AVEVA |
Plant SCADA |
Real-Time alarms |
Native, proprietary |
AVEVA |
Plant SCADA |
Historical values |
Native, proprietary |
AVEVA |
Plant SCADA |
Historical alarms |
Native, proprietary |
ControlMaestro |
Wizcon/Control Maestro |
Real-Time values |
Native, proprietary |
ControlMaestro |
Wizcon/Control Maestro |
Real-Time alarms |
Native, proprietary |
ControlMaestro |
Wizcon/Control Maestro |
Historical values |
Native, proprietary |
ControlMaestro |
Wizcon/Control Maestro |
Historical alarms |
Native, proprietary |
Emerson |
DeltaV SCADA |
Real-Time values |
Custom, OPC based |
Emerson |
DeltaV SCADA |
Real-Time alarms |
Custom, OPC based |
Emerson |
DeltaV SCADA |
Historical alarms |
Custom, OPC based |
Emerson |
DeltaV SCADA |
Historical values |
Custom, OPC based (New driver), Historical data access |
Emerson |
DeltaV SCADA |
Historical values |
Custom, OPC based (old driver for backward compatibility) |
Watlow (Eurotherm) |
Review database access |
Historical values |
Direct |
Watlow (Eurotherm) |
Review database access |
Historical alarms |
Direct |
Watlow (Eurotherm) |
Review Batch Monitor |
Real-Time values |
Direct |
Watlow (Eurotherm) |
UHH SQL database access |
Historical values |
Direct |
Watlow (Eurotherm) |
UHH SQL database access |
Historical alarms |
Direct |
Watlow (Eurotherm) |
UHH SQL DB Batch Monitor |
Real-Time values |
Direct, ODBC based |
Watlow (Eurotherm) |
UHH files access |
Historical values |
Native, SDK |
Watlow (Eurotherm) |
UHH files access |
Historical alarms |
Native, SDK |
Watlow (Eurotherm) |
UHH files Batch Monitor |
Real-Time values |
Native, SDK |
Watlow (Eurotherm) |
Eurotherm controllers |
Real-Time values |
Modbus based |
Watlow (Eurotherm) |
Data Review |
Historical alarms |
Direct, ODBC based |
Watlow (Eurotherm) |
Data Review |
Historical values |
Direct, ODBC based |
Watlow (Eurotherm) |
Data Review batch monitor |
Real-Time values |
Direct, ODBC based |
General Electric |
Cimplicity |
Historical values |
Direct, ODBC based |
General Electric |
Cimplicity |
Historical messages |
Direct, ODBC based |
General Electric |
Proficy iHistorian |
Historical values |
Direct, OLEDB based |
General Electric |
Proficy iHistorian |
Historical alarms and events |
Direct, OLEDB based |
General Electric |
Smart Signal |
Historical values |
Native |
General Electric |
iFix |
Real-Time values |
Native, proprietary |
General Electric |
iFix |
Real-Time alarms |
Native, proprietary |
General Electric |
iFix |
Historical values |
Native, proprietary |
General Electric |
iFix6+ |
Real-Time values |
Native, proprietary |
General Electric |
iFix6+ |
Real-Time alarms |
Native, proprietary |
General Electric |
iFix6+ |
Historical values |
Native, proprietary |
General Electric |
GE iHistorian |
Historical alarms |
Driect, OLEDB-SQL Hybrid Driver |
Geo SCADA |
Geo SCADA |
Real-Time values |
Native, proprietary |
Geo SCADA |
Geo SCADA |
Historical values |
Native, proprietary |
Geo SCADA |
Geo SCADA |
Historical alarms |
Native, proprietary |
InfluxData |
InfluxDB |
Historical values |
Direct |
Internal |
System |
Real-Time values |
Internal |
Internal |
System |
Historical values |
Internal |
Internal |
LUA Script |
Event frames |
Internal |
Internal |
LUA Script |
Historical values |
Internal, LUA based |
Internal |
WEB Manual Driver |
Historical values |
Internal, manual data entry |
Loytec |
LWEB 801 database server |
Historical values |
Direct |
Loytec |
LWEB 801/900 |
Historical values |
Direct |
Mitsubishi |
CC-LINK (using SLMP) |
Real-Time values |
Ethernet |
Mitsubishi |
Mitsubishi HVAC |
Real-Time values |
serial (RS232) |
Open protocol |
Excel files |
Real-Time values |
Access to Excel files values |
Open protocol |
Advanced ODBC |
Historical values |
Advanced ODBC driver |
Open protocol |
Advanced ODBC |
Historical Alarms |
Advanced ODBC driver |
Open protocol |
OLEDB |
Historical values |
General OLEDB driver |
Open protocol |
OLEDB |
Historical Alarms |
General OLEDB driver |
Open protocol |
CSV files |
Historical Alarms |
Import from csv files |
Open protocol |
CSV files |
Real-Time values |
Import from csv files |
Open protocol |
CSV files |
Real-Time alarms |
Import from csv files |
Open protocol |
MQTT |
Real-Time values |
IoT online driver |
Open protocol |
BACnet |
Real-Time values |
Native |
Open protocol |
BACnet |
Real-Time alarms |
Native |
Open protocol |
BACnet |
Historical values |
Native |
Open protocol |
SNMP |
Real-Time values |
Native, SNMP ver.1 and 2 |
Open protocol |
ODBC |
Historical values |
ODBC driver |
Open protocol |
ODBC |
Historical alarms |
ODBC driver |
Open protocol |
OPC |
Real-Time alarms |
OPC AE |
Open protocol |
OPC |
Real-Time values |
OPC DA |
Open protocol |
OPC |
Historical values |
OPC HDA |
Open protocol |
OPC |
Historical values |
OPC UA |
Open protocol |
OPC |
Real-Time values |
OPC UA |
Open protocol |
FCI |
Real-Time values |
Serial |
Open protocol |
Modbus |
Real-Time values |
TCP/IP, Serial, ASCII, JBUS, RS232 |
Remote |
Remote |
Real-Time values |
Internal, remote connector |
Remote |
Remote |
Historical values |
Internal, remote connector |
Rockwell |
RsView |
Historical values |
*.dbf archives, direct |
Rockwell |
FactoryTalk View database |
Historical values |
Direct, Database |
Rockwell |
FactoryTalk View database |
Historical alarms |
Direct, Database |
Rockwell |
FactoryTalk |
Historical values |
Native, Web Services |
Rockwell |
FactoryTalk |
Historical alarms |
Native, Web Services |
Rockwell |
FactoryTalk |
Real-Time values |
Native, Web Services |
Rockwell |
Rockwell PLC |
Real-Time values |
Native, proprietary |
Schneider |
ION |
Historical values |
Direct |
Schneider |
StruxureWare |
Historical values |
Native, Web services |
Siemens |
Desigo CC |
Historical values |
Web services |
Siemens |
Desigo database |
Historical values |
Direct |
Siemens |
WinCC SCADA |
Real-Time values |
Native, proprietary |
Siemens |
WinCC SCADA |
Real-Time alarms |
Native, proprietary |
Siemens |
WinCC SCADA |
Historical values |
Native, proprietary |
Siemens |
WinCC SCADA |
Historical alarms |
Native, proprietary |
Siemens |
PLC S7 |
Real-Time values |
Native, SDK |
Siemens |
PLC S7 -200/300/400 |
Real-Time values |
Native, TCP/IP |
StreamX for ACC |
ACC database |
Historical values |
Direct, ODBC based |
Techno Trade |
TVIEW HMI |
Historical values |
Native SDK |
Techno Trade |
TVIEW HMI |
Historical alarms |
Native SDK |
Trihedral |
VTScada |
Real-Time values |
Native, proprietary |
Trihedral |
VTScada |
Historical values |
Native, proprietary |
Trihedral |
VTScada |
Historical alarms |
Native, proprietary |
Yokogawa |
Batch monitor |
Historical Files |
Native SDK |
Yokogawa |
Yokogawa files access |
Historical Files |
Native SDK |
Yokogawa |
Yokogawa files access |
Historical Messages |
Native SDK |
1-888-665-3678 (US + Canada)