TOP Server Modbus RTU Serial Overview
Part of SuiteMulti-Industry

TOP Server Modbus TCP Ethernet Client/Server OPC Driver

High-Performance Connectivity for Modbus TCP Devices

4.8(118 reviews)
256 Devices

Up to 256 devices per channel.

100 Channels

Supports up to 100 communication channels.

65K Addressing

Full Modbus address range up to 65535.

Protocols

Supports RTU, ASCII, and serial Modbus networks.

Product Overview

The Modbus TCP Ethernet driver works in conjunction with TOP Server to provide data exchange between OPC UA, OPC DA, SuiteLink and DDE clients and PLCs using the Modbus TCP Ethernet protocol.

This driver implements both client and server capabilities in the same driver, allowing communication with both server devices (PLCs, RTUs, other control and field devices) and client devices or systems (HMIs, SCADAs, DCS, PLCs, etc). Data acquisition is optimized based on upstream client demand while data integrity is ensured using extensive error handling.

The Modbus Ethernet driver also features direct integration with Modicon Concept and ProWORX programming packages, allowing users to directly import the tags from the PLC into TOP Server.

Why Choose This Driver?

Proven benefits that help you deploy faster and operate more reliably

Function Codes

Supports standard Modbus function codes in both decimal and hexadecimal formats.

Address Range

Full address range support up to 65535 across coils and registers.

Addressing Options

Supports both decimal and hexadecimal addressing methods.

Data Types

Supports all memory and data types, including word, float, long, and double.

String Support

Includes string data type support for internal registers.

Block Reads

Supports string block reads and 32-bit data handling across two registers.

Connectivity

Enables Modbus bridging and routing to Modbus Plus, RTU, and ASCII, with DNS naming support.

Configuration

Includes CSV tag import, dynamic tag creation, and configurable inter request delay for performance control.

"I've been a Software Toolbox customer for many years. Customer service and technical support have *always* been the best of any vendor I've worked with."

Jason Shack

Automation Engineer

Key Features & Benefits

Everything you need for reliable Modbus RTU serial connectivity

Scalability

Supports up to 1024 channels and 8192 devices per channel, with actual limits depending on system resources.

Tag Generation

Automatic tag database generation supported from Concept or ProWORX for faster configuration.

Connectivity

Supports Modicon Ethernet to Modbus Plus bridging and flexible socket usage for optimized resource management.

Data Handling

Supports word and byte order swapping, along with user definable block sizes for efficient data transfer.

Technical Specifications

Protocol

Supports Modbus TCP over Ethernet for industrial communication.

Network Connectivity

Supports TCP and IP Ethernet, including cellular modem connections.

Supported Devices

  • Applicom: Generic Modbus, TSX Premium, TSX Quantum
  • Fluenta FGM
  • Instromet
  • Mailbox
  • Modbus Ethernet
  • Roxar RFM
  • Modbus TCP Clients
  • Modbus TCP to Modbus Plus Gateways

Note: Supports Modicon PLCs, JBUS RTU devices, and any Modbus RTU-capable device from any manufacturer. Includes specialized support for flow computers, industrial drives, and flow meters.

Modbus RTU Serial Key Features Include

  • ScalabilitySupports up to 1024 channels and 8192 devices per channel, with actual limits depending on available system resources.
  • IntegrationAutomatic tag database generation from Concept or ProWORX, along with support for Modicon Ethernet to Modbus Plus bridging.
  • PerformanceSupports flexible socket usage, word and byte order swapping, and user definable block sizes for optimized data handling.

Modbus RTU Serial Advanced Features Include

  • Applicom ModelSupports Applicom device model with specialized address syntax and three sub models.
  • Address ModifiersIncludes address level byte and word switching modifiers for Applicom models.
  • Address ConfigurationAdjustable address base settings, allowing selection of 0 or 1 based addressing.
  • Write ControlSelectable function codes for single address write operations.
  • Data FormattingSupports word and byte order swapping for 16 bit and 32 bit data types.
  • Block OptimizationUser definable read block sizes for efficient data access.
  • String HandlingSupports holding register memory as string data with selectable byte order.
  • Tag GenerationAutomatic tag database generation from Concept or ProWORX.
  • PerformanceOptimized communications with separate channels per device and up to 10 TCP sockets per device.
  • Advanced FeaturesIncludes channel serialization, NIC selection, Modbus server support, configurable socket termination, expanded blocking modes, and advanced diagnostic statistics tags.

Customer Reviews

Customer ratings

4.8 out of 5

118 global ratings

5 star
75%
4 star
15%
3 star
7%
2 star
2%
1 star
1%
John M.
Excellent reliability and performance

Reviewed in the United States on November 15, 2023

Verified Purchase

We've been using this driver for over 6 months in our manufacturing operations and it has been rock solid. The Modbus RTU connectivity is stable, data accuracy is excellent, and the support team has been very responsive when we had questions during setup. Highly recommended for industrial applications.

Sarah K.
Easy setup and great documentation

Reviewed in the United States on October 3, 2023

Verified Purchase

As a systems integrator, I appreciate how straightforward the setup process was. The documentation is comprehensive and the driver performed exactly as expected. Integration with our SCADA system was seamless.

Mike R.
Good product, minor config challenges

Reviewed in the United States on September 20, 2023

Verified Purchase

Overall very satisfied with the driver. Had some initial configuration questions but support walked me through it. Once configured, it's been running smoothly for 3 months without issues. Would give 5 stars if the initial setup was more intuitive.

Get Started Now

The full TOP Server product runs in a 2-hour demo mode until licensed. After 2 hours, simply restart the TOP Server service to reset the demo timer. Start your free trial today or speak with a connectivity expert.

Connect with Us

1-888-665-3678 (US & Canada Toll-Free)+1-704-849-2773 (Global)Support Portal