Reliable Connectivity for GE (now Emerson) PLCs via GE CCM Serial Protocol
This driver is only available as part of the following TOP Server driver suites:
Key Features
Protocols
Free Trial
Customer Rating
The GE CCM Serial driver works with TOP Server® to provide data exchange between OPC clients (UA, DA, SuiteLink, DDE) and GE PLCs via the GE CCM Serial Protocol. It features specialized support for GE Series Six PLCs with expanded I/O area access, and extensive error handling ensures data integrity.
This driver is available in the following TOP Server driver suites: TOP Server GE Suite, TOP Server Manufacturing Suite.
Proven benefits that help you deploy faster and operate more reliably
Enhanced support for GE Series Six PLCs with expanded I/O area access and comprehensive error handling
Support for multi-drop configurations with Device IDs 1–90 for efficient serial network management
Automatic dial configuration and multiple phone numbers management for remote connectivity
Automatic tag database generation using CSV import for rapid deployment and configuration
"Outstanding reliability and performance. This driver has been running flawlessly in our production environment for over a year."
John Anderson
Automation Engineer, Manufacturing Solutions Inc.
Everything you need for reliable industrial connectivity
Channels – 100; Devices per Channel – 90 for reliable GE CCM serial network deployments.
Supports automatic tag database generation via CSV import for rapid configuration.
Supports multi-drop configurations with Device IDs 1–90 over RS-232 and RS-485.
Automatic dial configuration and multiple phone number management for remote device access.
Supports Ethernet Encapsulation via Ethernet/Serial converters and terminal servers.
Optimizes communication by automatically skipping unresponsive devices to maintain throughput.
Protocol
GE CCM Serial
Networks
Serial RS-232, RS-485; Ethernet Encapsulation
Max Channels
100
Devices per Channel
90
Max Data Array Size
128 bytes
Memory Types
I, Q, R
License Type
Perpetual
Note: Supports GE Series 90-30, 90-70, Series Five, and Series Six PLCs via GE CCM Serial Protocol.
Everything you need to get started, configure, and troubleshoot your driver
Watch step-by-step video tutorials covering installation and configuration
View →Get started quickly with TOP Server
View →Troubleshooting tips and solutions for TOP Server
View →Complete driver documentation with setup instructions and configuration examples
Download →View the complete TOP Server release history and version information
View →